Logo

AZ00126340

Sold 312

Difficulty Icon: Normal
Normal
15 - 20 minutes

$21.06

$23.39

puzzle

Not sure if this is the right part?

Check now

[Lifetime Warranty] 3 Pole 40 Amp Contactor 120 VAC Coil Definite Purpose Contactor image 0
[Lifetime Warranty] 3 Pole 40 Amp Contactor 120 VAC Coil Definite Purpose Contactor image 1
[Lifetime Warranty] 3 Pole 40 Amp Contactor 120 VAC Coil Definite Purpose Contactor image 2
[Lifetime Warranty] 3 Pole 40 Amp Contactor 120 VAC Coil Definite Purpose Contactor image 3
[Lifetime Warranty] 3 Pole 40 Amp Contactor 120 VAC Coil Definite Purpose Contactor image 4
[Lifetime Warranty] 3 Pole 40 Amp Contactor 120 VAC Coil Definite Purpose Contactor image 5
[Lifetime Warranty] 3 Pole 40 Amp Contactor 120 VAC Coil Definite Purpose Contactor image 6
AZ00126340

[Lifetime Warranty] 3 Pole 40 Amp Contactor 120 VAC Coil Definite Purpose Contactor

Sold 312

Difficulty Icon: Normal
Normal
15 - 20 minutes

$21.06

$23.39

Save $2.33
In Stock

Fast delivery

puzzle

Confirm the fit for your model

Find your model number and check it here to see if the part fits.


Description

3 Pole 40 Amp Contactor 120V Coil DP Contactor HVAC Contactor 42CF35AF Equivalent

Key Features

  • Type: Definite Purpose (DP) Contactor
  • Poles: 3 Pole
  • Full Load Amperage (FLA): 40 Amp
  • Coil Voltage: 120V AC
  • Frequency: 50/60 Hz
  • Contacts: Silver alloy construction
  • Certifications: UL Listed, A2L refrigerant system compliant

Replaces / Cross-Reference Part Numbers

  • Siemens / Furnas: 42CF35AF
  • Eaton: C25DNF340A

Compatibility & Fitment

  • Designed for HVAC systems, including air conditioners and heat pumps.
  • Direct replacement for 3-pole contactors with a 120V coil.
  • Suitable for applications requiring a 20A, 25A, 30A, 35A, or 40A contactor.

When to Replace

  • Outdoor condenser unit fails to start.
  • Visible arcing, pitting, or burning on the contacts.
  • Loud buzzing or chattering noise from the contactor during operation.
  • Coil shows no continuity when tested with a multimeter.
  • Contactor is physically stuck in the open or closed position.

Installation Tips

  • Disconnect all electrical power at the circuit breaker and service disconnect before installation.
  • Confirm power is off using a voltage meter.
  • Photograph or label existing wire connections to ensure correct reassembly.
  • Securely tighten all terminal connections to prevent overheating.
  • Ensure the replacement contactor's voltage and amperage ratings match the system's requirements.
Color
Black

Voltage
120

Material
Copper

Item Model Number
3 Pole 40 Amp 120V