Logo

AZ00126340
Difficulty Icon: Normal
Normal
15 - 20 minutes

$21.06

$23.39

puzzle

Not sure if this is the right part?

Check now

[Lifetime Warranty] 3 Pole 40 Amp Contactor 120 VAC Coil Definite Purpose Contactor image 0
[Lifetime Warranty] 3 Pole 40 Amp Contactor 120 VAC Coil Definite Purpose Contactor image 1
[Lifetime Warranty] 3 Pole 40 Amp Contactor 120 VAC Coil Definite Purpose Contactor image 2
[Lifetime Warranty] 3 Pole 40 Amp Contactor 120 VAC Coil Definite Purpose Contactor image 3
[Lifetime Warranty] 3 Pole 40 Amp Contactor 120 VAC Coil Definite Purpose Contactor image 4
[Lifetime Warranty] 3 Pole 40 Amp Contactor 120 VAC Coil Definite Purpose Contactor image 5
[Lifetime Warranty] 3 Pole 40 Amp Contactor 120 VAC Coil Definite Purpose Contactor image 6
AZ00126340

[Lifetime Warranty] 3 Pole 40 Amp Contactor 120 VAC Coil Definite Purpose Contactor

Difficulty Icon: Normal
Normal
15 - 20 minutes

Out of Stock
This item is no longer available. Please contact our customer service for more information
puzzle

Confirm the fit for your model

Find your model number and check it here to see if the part fits.


Description

3 Pole 40 Amp Contactor 120V Coil DP Contactor HVAC Contactor 42CF35AF Equivalent

Key Features

  • Type: Definite Purpose (DP) Contactor
  • Poles: 3 Pole
  • Full Load Amperage (FLA): 40 Amp
  • Coil Voltage: 120V AC
  • Frequency: 50/60 Hz
  • Contacts: Silver alloy construction
  • Certifications: UL Listed, A2L refrigerant system compliant

Replaces / Cross-Reference Part Numbers

  • Siemens / Furnas: 42CF35AF
  • Eaton: C25DNF340A

Compatibility & Fitment

  • Designed for HVAC systems, including air conditioners and heat pumps.
  • Direct replacement for 3-pole contactors with a 120V coil.
  • Suitable for applications requiring a 20A, 25A, 30A, 35A, or 40A contactor.

When to Replace

  • Outdoor condenser unit fails to start.
  • Visible arcing, pitting, or burning on the contacts.
  • Loud buzzing or chattering noise from the contactor during operation.
  • Coil shows no continuity when tested with a multimeter.
  • Contactor is physically stuck in the open or closed position.

Installation Tips

  • Disconnect all electrical power at the circuit breaker and service disconnect before installation.
  • Confirm power is off using a voltage meter.
  • Photograph or label existing wire connections to ensure correct reassembly.
  • Securely tighten all terminal connections to prevent overheating.
  • Ensure the replacement contactor's voltage and amperage ratings match the system's requirements.